What is the minimum mix design for RCC as per IS 456?

user-image
تم إضافة السؤال من قبل venkata satya uday bhaskar Guntupalli , Deputy manager , SEW INFRASTRUCTURE LTD
تاريخ النشر: 2015/04/13
Gideon Obuobi
من قبل Gideon Obuobi , Safety/Security Interface Specialist (Enec) , ADNOC

IS : 456-2000 has recommended that minimum grade of concrete shall be not less than M-20 in reinforced concrete work. Design mix concrete is preferred to nominal mix. If design mix concrete cannot be used for any reason on the work for grades of M-20 or lower, nominal mixes may be used with the permission of engineer-in-charge, which however is likely to involve a higher cement content.