ابدأ بالتواصل مع الأشخاص وتبادل معارفك المهنية

أنشئ حسابًا أو سجّل الدخول للانضمام إلى مجتمعك المهني.

متابعة

Why is used a cement unit pump when they make leak off test?

user-image
تم إضافة السؤال من قبل Virgil Nedelcu , Nightpusher , S.C. DAFORA DRILLING S.A
تاريخ النشر: 2015/05/21
Ahmed abd El-Maksoud
من قبل Ahmed abd El-Maksoud , Completion Engineer , Baker Hughes

Using a cement unit give you the advantage of recording accurate  pumping pressure and the volume and give you the required   pressure and you can get charts for that in hard copy and some cement units provide soft copy also. You also can pumping with any rate even small rate equal to .25 Bbl or less.

Pedro Masiero Junior
من قبل Pedro Masiero Junior , Field Engineer , HALLIBURTON ENERGY SERVICES

Another secondary reason it´s becasuse cement pumps are more reliable than regular pumps when subject to high pressures. Thats particularly importat for older rigs. The pressures may also be measured by LWD tools if your cement gauges aren´t reliable, so there´s plenty of room for redundancy.

Virgil Nedelcu
من قبل Virgil Nedelcu , Nightpusher , S.C. DAFORA DRILLING S.A

Yes it's true but i didn't ask what mean leak off test. I think that in a cement line we have hight pressure and a low volume and that can be easy monitoring. What you think about that?

kayode owoeye
من قبل kayode owoeye , trainee geoloical engineer and full time geologist at bitto , department of petroleum resources and bitto engineering

the leak off test establish a practical  value of the input into the  fracture pressure and indicate the limit of the amount of pressure that can be applied tothe well bore over the next section of the drilled ol

المزيد من الأسئلة المماثلة

هل تحتاج لمساعدة في كتابة سيرة ذاتية تحتوي على الكلمات الدلالية التي يبحث عنها أصحاب العمل؟