ابدأ بالتواصل مع الأشخاص وتبادل معارفك المهنية

أنشئ حسابًا أو سجّل الدخول للانضمام إلى مجتمعك المهني.

متابعة

Does the slip of an induction motor normally depend on the Core loss Component?

user-image
تم إضافة السؤال من قبل Muhammad Qasim , Senior Electrical Engineer , Energy Associates (SMC Ptv.) Ltd.
تاريخ النشر: 2016/07/27
manzoor ummar
من قبل manzoor ummar , Electrical Engineer , Tata Consulting Engineers

I could find a relation between rotor Cu loss and slip.

Rotor Cu loss = Slip * Rotor input

But there is no relation between no load losses and slip. No-load loss depends on voltage.

Bilal Abid
من قبل Bilal Abid , Management Trainee (Electrical) , PTCL

It does not depend on core loss componenet .

As slip=(Ns-Nr)/Ns

from the relation above its only depend on synchronous speed Ns , rotor speed Nr and shaft torque of motor

 

مستخدم محذوف‎
من قبل مستخدم محذوف‎

The answer is NO

Slip= (Ns-Nr)/Nr

Ns= Synchronous Speed

Nr= Rotor Speed

(Slip depends on Synchronous and Rotor Speed, not on core loss components)