ابدأ بالتواصل مع الأشخاص وتبادل معارفك المهنية

أنشئ حسابًا أو سجّل الدخول للانضمام إلى مجتمعك المهني.

متابعة

Why the vibration system from bentely nevda and pcb company using the voltage as a reference to measure on the rotating shafts and equipments?

user-image
تم إضافة السؤال من قبل MOHAMED ELMELEGY , instrument engineer , Segas LNG plant
تاريخ النشر: 2013/10/07
Saikumar Panchamurthy
من قبل Saikumar Panchamurthy , Vibration Technician , aramco

This systems are using proximities which works under eddy current principle (measuring gap voltage) which is very stable during rotational

Fady Adly
من قبل Fady Adly , Machinery Solutions Consultant , Nile Advance Technology & Commerce - NATCOM

The systems you mentioned use what is known as a "proximity probe" or "eddy current probe" to measure shaft relative vibration (relative meaning relative to the bearing housing; the stator).

Without getting into unecessary details; the output of this probe is a signal known as a "dynamic voltage signal" which is basically an electrical signal which has a voltage which varies (almost) linerally with the distance between the probe tip and the shaft surface. As Mohamed mentioned, this signal has two components; the "DC" component which represents the "average" shaft position and the "AC" component which represents the shaft's vibration or its motion from the average position.

 

Hope this helps!

MOHAMED ELMELEGY
من قبل MOHAMED ELMELEGY , instrument engineer , Segas LNG plant

They using he voltage as a reference of the gap between the shaft and the sensor it depends on the induced EMF which is generated due to the magnetic filed generated by the sensor and it cut by the shaft o detect where the shaft is present  

 

So you can find that using a distance gap by a DC volt which will be the reference for the  mechanical shaft in the zero position and the moving shaft will be moving up and down around the reference line a round the gap. 

Zain UL Abideen Shah
من قبل Zain UL Abideen Shah , TRS Engineer , wellserve OIL FIELD PVT. CO.

May be it Keep the SHaft Stable At that refernce Volatage and Output will be Without any Fluxtuation thank you