ابدأ بالتواصل مع الأشخاص وتبادل معارفك المهنية

أنشئ حسابًا أو سجّل الدخول للانضمام إلى مجتمعك المهني.

متابعة

Limits on attenuation for fiber optic route about splicing points and connectors?

user-image
تم إضافة السؤال من قبل ahmed ezat
تاريخ النشر: 2017/05/15
Sajad ali
من قبل Sajad ali , Technical Product Specialist , ABANA Enterprise group

fussison splice must be lest than 0.05dB and conector loss is must be less than 0.5 dB. otherwise the auttenuation will occures.

Mohamed Yassine Belalia
من قبل Mohamed Yassine Belalia , Contractor , ETS BELALIA

Individual Splice Loss of0.05 dB and total splice loss cannot increases0.1 dB.

Connector Loss should not increase more than0.5 dB.

Edmond Ivan Asilo
من قبل Edmond Ivan Asilo , Telecom engineer site supervisor , Hayat Communication LLC

The limits on attenuation for fiber optic route for splicing loss are from 0.1dBM to 0.5 dBM while for the Connector loss is 0.75 dBm

Sohail Anwar
من قبل Sohail Anwar , FOC Engineer , STC solutions

Typical splice loss must not be more than 0.1db while ideal connector loss must not be more than 0.5db.

while fiber span loss varies according to the used wave length.

المزيد من الأسئلة المماثلة