What is water cement ratio for various type of concrete?

user-image
تم إضافة السؤال من قبل Soumya Barman
تاريخ النشر: 2017/07/13
Mustafa Raza Khan
من قبل Mustafa Raza Khan , Laboratory Supervisor , Readymix Qatar

w/c ratio normally ranges between 0.4 and 0.5

Michael El Ghazal Mouawad
من قبل Michael El Ghazal Mouawad , Project Engineers , Petrofac LLC

water cement ratio is variable depending on:

- Cement type

- Concrete strength

- Addmixtures

w/c ratio normally ranges between 0.4 and 0.5

Saurabh Rai
من قبل Saurabh Rai , Junior Lab Engineer , Jaiprakash Associates Limited

W/C stands watar cement ratio. It is selected on requirements of grades of concrete to be placed for various types of concrete structures which is mentioned in the Tables of different internal standards as ASTM, ACI BS-EN & Indian Standards.

Awad Alibrahim
من قبل Awad Alibrahim , Civil Engineer , Saudi Consulting Service

max 0.45 for cement type 1

max 0.50 for cement type 5

Sundara Subramaniyan
من قبل Sundara Subramaniyan , Shift Engineer , Najran cement company

Water Cement ratio is the weight of water to the weight of cement in concrete. Generally the range is 0.4 to 0.6

The more water will reduce the strength of concrete.

23% of water is sufficient for cement to start reaction. More water in concrete leads aggrigates to settle down.

Danish Alam
من قبل Danish Alam , Civil Site Engineer , Galaxias Pvt Ltd.

The watercement ratio is the ratio of the weight of water to the weight of cementused in a concrete mix. A lower ratio leads to higher strength and durability, but may make the mix difficult to work with and form. Workability can be resolved with the use of plasticizers or super-plasticizers.

Different concreate have their different water-cement ratio and they are as follows-

M10 (1:3:6) - 34 to 36 lit(Water),Cement - 226kgsM15 (1:2:4) - 29 to 32 lit(Water),Cement - 313kgsM20 (1:1½:3)- 26 to 30 lit(Water),Cement - 404kgsM25 (1:1:2) - 21 to 27 lit(Water),Cement - 563kgs

shamsher ali
من قبل shamsher ali , Lab Technician , Al-Mumayaz independent lab Riyadh

you have to calculate it according to the required strength.