It's standard section using predimensioning method which is calculated like the followingS = H x (1/40 ~1/30)H : is the total hight of the building ( H = h x n )h : a single floor hightn: number of floorsEg : for a building of5 floors high, and3.06m height for each floorS =5 x3.06 x1/40 =15.3 x0.025 =0,3825 then S =40 cm section or0.4 m sectionPS : for a building with a height more than3 ( three floors) curtain walls must be considered
The best section to corner column is according calculation.