You are using Breathing Apparatus set. During the rescue operation cylinder saw50 bar pressure warning whistle start. Now rescuer what should you do?

you are using Breathing Apparatus set. During the rescue operation cylinder saw only50 bar pressure and also sounding warning whistle. Now, rescuer what should you do ?

user-image
Question added by NazarAli Abbasbhai , Fire Marshal , Expertise contracting company Ltd
Date Posted: 2015/07/17
Waqar Ghani
by Waqar Ghani , Fire Fighter , Emergency Rescue Service (Rescue-1122)

warning whistle indicate that its time to leave the confined place because the pressure in breathing apparatus is low and hardly work up to 10 to 15 minutes.  

Mbuso Nkomo
by Mbuso Nkomo , Fire fighter , Bulawayo Fire and Ambulance Services

I SIGNAL MY PARTNER TO IMMEDUATELY LEAVE THE TOXICATED AREA TO SAFETY: OUT OF THE BUILDING

Tony Ahamefule
by Tony Ahamefule , Industrial Fire Fighter , Shell Petroleum Development Company

You must retreat immediately you hear your BA warning sound