Start networking and exchanging professional insights

Register now or log in to join your professional community.

Follow

What is the equation used to drainage design(under gravity pipe) and what is the minimum slope we can use?

user-image
Question added by Mohamed Shahawy , Senior Mechanical Engineer , Ebtekar al Memar For Trading
Date Posted: 2016/01/10

3% + V>2-2,5m/s according to the severity of the fractions in the water

 

lazhar boubendir
by lazhar boubendir , رصاص , zizou

V = (1.49/n)(Rh2/3)(S1/2),

More Questions Like This