Start networking and exchanging professional insights

Register now or log in to join your professional community.

Follow

What's the root cause if reciprocating compressor getting outlet temperature higher?

user-image
Question added by Yasir Hussain Syed , Sr. Mechanical Technician , Saudi Aramco Shell Refinery
Date Posted: 2016/03/17
Rashid Minhas
by Rashid Minhas , technical maintenance supervisor , Amco

in proper lubrication sucation and discharge valve leakage

javed mansoor
by javed mansoor , Deputy Manager , Glaxosmith Kline

1- Faulty pressur gauge or suction filters chocked.

2 - Check valve is not properly working on main discharge line.

3 - Poor prforance of intermidiate cooler ( insufficiant water flow )

4 - Water jackets need cleaning

5 - Comprrssor outlet valves seats are leaking.

6 - Ferection due to improper lubrication ( oil filters chocking ) 

Muniyandi Thangasamy
by Muniyandi Thangasamy , Control room panel operator , Qatar petroleum

1.Loading valve plates damage

2.Inter satge coller low coooling effect.

3. Discharge line partialy blockage or retriction in discharge line

Rami Adel Ammari
by Rami Adel Ammari , Senior Technical Engineer , TotalEnergies

The three causes for high discharge temperatures are:

 

  • High condensing temperature.

     

  • Low evaporator pressures and temperatures.

     

  • High compression ratios.

Siamak Habibpanah
by Siamak Habibpanah , MANITENANCE MANAGER , Taurus Arm for Power Generation - Combined Cycle Power Plan

VALVE OR VALVES (SUCTION OR DISCHARGE) DON'T WORK PROPERLY. LEAKAGE COULD BE THE MAIN REASON.

 

Vaqas Ali Khan
by Vaqas Ali Khan , Deputy Manager , fauji fertilizer bin qasim limited

Temperature always increases when fluid compresses.

Higher then design is due to wearing of internal parts.

Deleted user
by Deleted user

Lubrication problem and also when the air compressor is running with high discharge pressure than what required at the end use.

Muhammad Nadeem
by Muhammad Nadeem , Mechanical Technician , Hub power Station Ltd Pakistan

1 due to PI( pressure indicator faultily )

2 if discharge valve leak

3 inlet gas temperature is  high  dueto inter cooler problem  

6 due to cylinder  jack ting  service  temperature issue 

Muhammad Bilal Aslam
by Muhammad Bilal Aslam , Mechanical Maintenance Technician , FFBL Karachi

may be caused in

1- cooling system

2-  lubrication system.

3- exhaust valve problem 

Mark Duncan
by Mark Duncan , Mechanical Inspection Instructor , Itqan

There can be many differing causes, Compressors by their very mechanical nature of how they use brute force to compress air tends to produce a higher outlet temperature anyway.

High compression Ratio's can be a factor which is possible if the unit has been geared up or the engine sped up in an attempt to get more CFM out of the unit, this leads to higher temperatures (bad cooling) of both the compressor and the power unit which generally highlights ineficiencies in the overall design of modified units being asked to more than their original design specified.

General wear and tear and improper maintenance can have a significant effect on a units performance which usually leads to inssufficient cooling of a unit.

 

tarek aziz
by tarek aziz , INGENIEUR DE CONDUITE ET MAINTENANCE , INTER SHIPPING SARL

unsufficient cooling of the compressor

More Questions Like This