Register now or log in to join your professional community.
For the thickness of 2 important to the X Ray.ultrasound test Depending on the situation
Ressuage
He can use guided wave ultrasonic methode.
Best Regards
Ayman
here ultrasonic testing should be implemented, depending upon the sheet dimesnsions and apparatus available, Phase-Array or guided wave can be utilized.
It depends on bonding with which material.
For metal Ultrasonic will be the best technique for tesing for tesing debonding, but then Thickness of Al plate is very low i.e.2 mm.