Start networking and exchanging professional insights

Register now or log in to join your professional community.

Follow

What is the optimum flow velocity inside pipes and why we should avoid high and low velocity inside them?

user-image
Question added by Ali Soufan , HVAC Mechanical Engineer , Chehimi Cooling
Date Posted: 2017/10/02
Lutfi Al-saeed
by Lutfi Al-saeed , Maintenance Engineer , Al-Adiyat Al-Saree’ah

According to UPC the maximum velocity for domesticwater upply pipes is 3 m/s and the preferred 1.2 m/s the flow velocity are limited for comfortable issues and fixture life 

Ahmad Hisham Almasri
by Ahmad Hisham Almasri , Sr. MECHANICAL ENGINEER , HDP overseas

0.7-2.5 M/S,  high velocity cause erosion and corrosion in pipes in addition to noise otherwise, low velocity will increase the cost of the project 