is air gap is required for external cladding ?

user-image
Question added by Dinu Mathew Thomas , Commerical Interior designer , Symmetrics development services
Date Posted: 2018/08/17
Mubarak Yusuf
by Mubarak Yusuf , Structural Engineer , Xmatrix 369 Nig ltd

Yes it is required for external cladding

Reinaldo Martínez
by Reinaldo Martínez , Architectural design, project management. , Arquitectura Obra Magna S. A.

It depends on the kind of cladding. Some materials, like stones, need to be attached directly on the building envelope. Some curtain-wall use the total room space as air gap. And a few synthetic cladding can be placed with a more or less ample gap, calculated after the heat of the direct sun impact on the building, across the sun yearly track.  

Tomasz Pacyna
by Tomasz Pacyna , Senior Project Manager , JUCON

No, but it's much better when there is one for the airflow that prevents building overheating. 

SAMEH ABOUELEID
by SAMEH ABOUELEID , Quality Control Projects Manager , Rowad Modern Engineering ( RME ), Cairo

sure

Leave a ventilation gap of 22 to 25 mm behind the cladding 

Hossam Mustafa Gharib Hussien Hussien
by Hossam Mustafa Gharib Hussien Hussien , architecture engineer , CHINA STATE CONSTRUCTION ENGINEERING COOPERATION

Yes Because it gives you the capability to install thermal insulation and gives you good chance to level the cladding to be vertical without being stopped by any imperfections in the concrete or the block works   

Tajammul  Husain
by Tajammul Husain , Site supervisor , Al Arwanan est for Gen Contracting

Air gap is not required but there will be created a gap between the two panel of cladding that will be filled by backing roads and sealant.

Because air Condition are most important .

Muhammad Bilal
by Muhammad Bilal , QAQC Engineer / Project engineer , Ascor Engineering Development

Its Depends Types of the Cladding.

 

MD SAYED  HOSSAIN
by MD SAYED HOSSAIN , Sr. Sales and Service Engineer , Energypac Power generation Ltd

No need to take air gap in external cladding