Trending Gears Discussions

Follow

Ask the Community


Ask any professional question and get answers from other specialists.

Stream language
sandesh chawla's image
Question added by sandesh chawla Mechanical Gulf Nations for Construction Materials Co
8 years ago
Answers:
3
Followers:
Views:
129
Vote Count:
0
Answer should contain a minimum of 25 characters.
Muthukumar Govindhasamy's image
Question added by Muthukumar Govindhasamy QUALITY CONTROLLER SKS AUTOMOBILES
8 years ago
Answers:
4
Followers:
Views:
411
Vote Count:
0
Answer should contain a minimum of 25 characters.
shehryar islam's image
Question added by shehryar islam operations engineer (chemical engineer) ocean pakistan limited
11 years ago

Is there any technique to check whether a gear pump is fully primed or not before operation?‎

the pump produce a sound when we start it and not buildup the required pressure, is there any solution for that problem. i am thinking to install a booster pump to increa‎ ... See More

Answers:
8
Followers:
Views:
465
Vote Count:
3
Answer should contain a minimum of 25 characters.
mohammed abdelall's image
Question added by mohammed abdelall Mechanical trainer ُEastern province cement co.
10 years ago
Answers:
1
Followers:
Views:
88
Vote Count:
0
Answer should contain a minimum of 25 characters.
Gaber Boraey's image
Question added by Gaber Boraey Maintenance Engineer lamps for lighting systems
7 years ago
Answers:
0
Followers:
Views:
37
Vote Count:
0
Answer should contain a minimum of 25 characters.
Mohammed Abduraqeeb Sultan Mohammed's image
Question added by Mohammed Abduraqeeb Sultan Mohammed Data Entry Technician + Technicion in Electrical Extension Department of Military Works
7 years ago
Answers:
0
Followers:
Views:
1
Vote Count:
0
Answer should contain a minimum of 25 characters.
Mohamed Harhash's image
Question added by Mohamed Harhash Night Electrician PMG) PAN MEDITERRANEAN GROUP )
7 years ago
Answers:
1
Followers:
Views:
6
Vote Count:
0
Answer should contain a minimum of 25 characters.
Mohamed Elboraie's image  
Answer added by  Mohamed Elboraie, Service Center Manager, Hilti Kuwait
11 years ago

Sir, if the pump was old, I recommend checking clearances between gears and gaskets. If not, you maybe face a cavitation problem. The first step is to diagnose the pump f ... See More

Muhammad Usman's image  
Answer added by  Muhammad Usman, Assistant Manager Operations, Lahore Electric Supply Company
7 years ago

To protect electrical devices like transformer, generator, motors from short circuit fault or any internal or external fault. Relays, Circuit Breakers, Fuses, etc are the ... See More

Muhammad Sualeh's image  
Answer added by  Muhammad Sualeh, Skilled Worker Machinist, Pakistan Steel Mills
10 years ago

for the sake of pump noise you have to open the pump and check the clearance between the gears and adjust the tolerance of the gears thay might be too conjusted or too fa ... See More