Question added by OMER MOHAMMED Operation And Maintenance Engineer Alsafaa Plastics Industry
7 months ago
Answers:
0
Followers:
Views:
125
Vote Count:
0
Answer should contain a minimum of 25 characters.
محمد  إبراهيم's image  
Answer added by  محمد إبراهيم, Project Manager ( pig projects) , MEP designe manager , HVAC & MEP Department Head, Alfouzan
7 days ago

Cooling towers to reduce the water temperature to be nearest to WBT DEPENDING ON THE RELATIVE HUMIDITY  OF THE AIR,LATENT HEAT TO EVAPORATE THE WATER TAKEN FROM THE WATER ... See More

محمد  إبراهيم's image  
Answer added by  محمد إبراهيم, Project Manager ( pig projects) , MEP designe manager , HVAC & MEP Department Head, Alfouzan
7 days ago

Cooling towers to reduce the water temperature to be nearest to WBT DEPENDING ON THE RELATIVE HUMIDITY  OF THE AIR,LATENT HEAT TO EVAPORATE THE WATER TAKEN FROM THE WATER ... See More

OMER MOHAMMED's image
Question added by OMER MOHAMMED Operation And Maintenance Engineer Alsafaa Plastics Industry
7 months ago
Answers:
0
Followers:
Views:
2
Vote Count:
0
Answer should contain a minimum of 25 characters.
SREEKANTH K R's image
Question added by SREEKANTH K R Electrical Engineer Interiors R Us
1 year ago
Answers:
0
Followers:
Views:
4
Vote Count:
0
Answer should contain a minimum of 25 characters.
jerry michael's image
Question added by jerry michael mechanical project engineer gast solar mechanics
4 years ago

Why would the pressure in a chilled water closed loop line decrease with out any leakage?‎

why pressure decrease with out any leakage in closed loop line system‎

Answers:
2
Followers:
Views:
322
Vote Count:
0
Answer should contain a minimum of 25 characters.
Muneeb Ali's image
Question added by Muneeb Ali Network Architect MEEZA Information Technology
6 years ago

Can we install fire dampers in hvac supply and return ductwork passing through shaft to different floors?‎

 The application is a food processing unit with no fire rated walls.  Any link to support the argument. Please advise‎

Answers:
15
Followers:
Views:
805
Vote Count:
0
Answer should contain a minimum of 25 characters.
Haytham Jouda's image
Question added by Haytham Jouda MEP Manager IHG
6 years ago

Preventing the chilled water pipes after the pressure test.?‎

after the water pressure test for chilled water pipes the system will not be used for a while, is there any possibility for the pipes to get rusted? what is the best solu‎ ... See More

Answers:
1
Followers:
Views:
301
Vote Count:
0
Answer should contain a minimum of 25 characters.