Communiquez avec les autres et partagez vos connaissances professionnelles

Inscrivez-vous ou connectez-vous pour rejoindre votre communauté professionnelle.

Suivre

If you have two Cisco router that running eigrp as a routing protocol to connect two building together

• Building one Marketing on the subnet192.168.20.0 /27 Sales on the subnet192.168.20.32 /27 Building two Marketing on the subnet192.168.20.96 /27 Sales on the subnet192.168.20.128 /27 The WAN link on the subnet192.168.10.4 /30 However you discover that the two building has lost the connectivity Here is [output cut] from R1 R1# show ip interface brief Serial0/0192.168.10.5 YES manual up up FastEthernet1/0192.168.20.1 YES manual up up FastEthernet2/0192.168.20.33 YES manual up up R1# show running-config router eigrp10 network192.168.10.4 ,0.0.0.3 network192.168.20.0 ,0.0.0.31 network192.168.20.32 ,0.0.0.31 neighbor192.168.10.6 Serial0/0 no auto-summary R1# show ip protocols Routing Protocol is "eigrp10" Outgoing update filter list for all interfaces is not set Incoming update filter list for all interfaces is not set EIGRP metric weight K1=1, K2=0, K3=1, K4=0, K5=0 [output cut] from R2 R2# show ip interface brief Serial0/0192 .168 .10.6 yes manual up up FastEthernet1/0192.168.20.97 YES manual up up FastEthernet2/0192.168.20.129 YES manual up up R2# show running-config router eigrp10 network192.168.10.4 ,0.0.0.3 network192.168.20.96 ,0.0.0.31 network192.168.20.128 ,0.0.0.31 neighbor192.168.10.5 Serial0/0 no auto-summary R2#show ip protocols Routing Protocol is "eigrp10" Outgoing update filter list for all interfaces is not set Incoming update filter list for all interfaces is not set EIGRP metric weight K1=1, K2=1, K3=0, K4=0, K5=0 Based on this information what is the problem that make the two building lost the connection between each other and how to solve it

user-image
Question ajoutée par Abdallah Yousif Nooreldayim Eltayb , IT Administrator , Cannes Hotel
Date de publication: 2014/08/12
Utilisateur supprimé
par Utilisateur supprimé

the K values in ROUTER2 is misconfigured and can be fixed by issue the command :

R2(config-router)#metric weights10100

 

Imtiyaz Shaikh
par Imtiyaz Shaikh , Assistant Manager,IT Network at National Bank of Kuwait , National Bank Of Kuwait - Nbk - United Arab Emirates

 

 

The K values on the second router is not matching with first router ,which is set to default as below.

By setting K value to default as below, neigborship will come up

 

Default values,

K1=K3=1

K2=K4=K5=0

 

 

R2(config-router)#metric weights10100

 

 

 

younes benamor
par younes benamor , Senior Network Engineer , Sonatrach Oil gas company

metric weight configuration

Mohamed Masthan
par Mohamed Masthan , Network Engineer , INTEGRAL SERVICES COMPANY W.L.L

Try matching the metric weights by changing the metric weight of router2 to10110. I hope this will solve the problem of connectivity

Mehul Mehta
par Mehul Mehta , Technical Consulting Engineer , Cisco Systems Inc

The K values should be matching on both ends. We see here that K2=1 on second router. Kindly set K2=0 and on2nd router and it should be fine.

Khaled Omar
par Khaled Omar , Senior Service Delivery Engineer , Dell Technologies

There are many things here needs to be modified, if you are looking for better and easier learning, more than only troubleshooting the neighbor relationship problem which can be solved by matching the k-values on both routers.

 

To enable EIGRP on the router interfaces, simply, you can use these network commands on both routers without using the wildcard mask:

 

Router(config-router)#network192.168.10.0

Router(config-router)#network192.168.20.0

 

If there are interfaces that you don't need EIGRP to be enabled on, simply, use the passive interface command.

 

There is no need for the static neighbor EIGRP command on both routers, as both routers will be EIGRP neighbors using dynamic neighbor discovery.

abdallah Osman Minini
par abdallah Osman Minini , Senior network and security engineer , Ebttikar Technology Company

You will need change the Metric 

Akram Khan
par Akram Khan , IT Technical Support , Dubai islamic Bank

Its pretty simple.Just change the metric

Sajjad Ali
par Sajjad Ali , Personal Assistant , Population welfare

We must change/configure metric values to equal on both routers i.e values of k. It should be same.