Communiquez avec les autres et partagez vos connaissances professionnelles

Inscrivez-vous ou connectez-vous pour rejoindre votre communauté professionnelle.

Suivre

In which correct place should we check gas detector before start Confined Space Entry Job? Thank You Very Much and Best Regards.

user-image
Question ajoutée par Nikolay Birkgaim , Senior Sulphur Plant Operator , The Republic of Kazakhstan,Atyrau NCOC.NV Company Karabatan Onshore Process Facilities
Date de publication: 2014/10/06
sanjay diwane
par sanjay diwane , Mechanical Forman , Bonatti S.p.A itlay

inside confined space there are three places top middle and bottom we check gas detector. for example we are working in oil tank first we take top side reading after middle and then bottom if main hole is in top side.

Janke Britz
par Janke Britz , Specialist: Capability Development , Sasol Group Technology

When doing work and using the gas detector, one must remember that you are testing for gas or oxygen levels. The gas detector should be lowered to the point of work by means of a rope, to determine the conditions that the people will work in. This information must be recorded on the permit to work.

More Questions Like This