Distillation column is running normal and sudenly disorder occured and all material is sucked in reflux drum and bottom is emptywhat causes ths?

50 sieve trays) In EDC (ethylene Dichloride plant separates light ends and isotropic mixture(edc &water) these light ends are corrosive so caustic soda is added, once condenser is damaged and replaced with new graphite vertical one.at first this column was OK but after15 days this problem occurred during this all column parameters (re-boiler steam and condenser cooling water are the same ) and column top pressure increases.

user-image
Question ajoutée par yousef muhammad abo ashoor , chemical engineer , TCI SANMAR CHEMICALS
Date de publication: 2015/02/11

IT IS CAUSED BY MANY REASONS

 

1. DUE to the heatexchanger problem

2.due to the distillation tray problems

3.poor perfomance of boiler feeder

 

samir  mukhtar
par samir mukhtar , Advisory Operator , Nghi son refinery and petrochemical

assalam -o-allekum

There are many reason of this

1- you cheack your feed specification.

2-if you reflux back section of tower tempreture is going down then check your control valve strokes if control valve is available otherwise pinch the pump discharge valve.

3-and my3rd suggesion is your tower trays or demester pads gone pluged.

Ahmed Abd Elaziz
par Ahmed Abd Elaziz , Assistant professor , جامعة كرري

السلام عليكم

 there are many resons lead to this case mainly :

1.Losses of heat  during the15 days occurse by the column wall(poor insulation).

2. Or a sudden change in the external condititon leads to a change in the reflux (the refluux ratio increase to1)

3.No feed .

thanks