the concrete work should not be allowed as failing slum test may indicates that it may effect the durability of concrete which is an important factor.

 

there are different thoughts on this , but if u considering the durability factor , it should not be allowed.

 

Ahsan Farid
par Ahsan Farid , QA/QC Civil Inspector , Al Fanar Construction

If Failed to achieve required slump;1-Add  superplasticizer 

http://www.manasanat.com/files/samim/fmng/mahsoolat/TechnologyVaTajhizateBeton/Admixtures/Conplast%SP.pdf

(we are using for Pump-ability & to achieve early days high strength + seconds admixture  mixing in Transit Mixer & your concrete is ready , continue pouring after mixing on the site.

Muhammad Faheem Yousufzai
par Muhammad Faheem Yousufzai , Quality Control Inspector , Natinal Engineering Services Pakistan

I will look to the steel structure.....if steel is congested i will go with the loose slump

Abubakr Hashem
par Abubakr Hashem , Site Engineer , Al Arif Contracting co. LLC

I would rather ask to take the slump test again after remixing again for few minutes to be sure that the mix is homogeneous and the slump result is true, however if it again failed i would unfortunately reject the truck

If on site slump fails just add some cement inside the TM mix properly by revolving for sometime and check the mix again all within the permissible setting time.

AMMAR-Nabeel RASHIDE
par AMMAR-Nabeel RASHIDE , project manager , Ibrahim AL Hajiry contracting co- Kuwait

 

 

     If  slump test fails  affect  to  required specification and bearing capacity of construction elements  I will not allow continue works  also depend of how many points fail if it within  rang tolerance  I will continue work second must be considering The density of iron to prevent of Nesting phenomenon of concrete

 

 

 

 

Mahmoud Zaher Tarakji
par Mahmoud Zaher Tarakji , مدير , أوال جاليري

No allow continue this work 

محمد يونس
par محمد يونس , مهندس مشرف , الشركة العامة للكهرباء

Change so as to give the required specifications.