In a Double glazed unit soft coated low emmissivity glass should be used on inner side or on the outside?

user-image
Question ajoutée par SUBHIRAMANIYAM krishnan subramaniam , Consultant , Sukrutham
Date de publication: 2015/07/26
Ragesh Ramadas
par Ragesh Ramadas , Sustainability Specialist , Bechtel

In a double glazed unit,we have4 surfaces ,ie #1 facing outdoors,#2 the inner surface of the glass on the exterior,#3 the suface of interior glass in contact with air gap and #4 facing the interiors.

The surface on which the low e coating has to be used is determined by which climate you are in,ie whether you prefer a heat gain to offset energy costs for heating(like in western countries) or to minimise heat gain as in hot climates(like middle east)

when low heat gain is preferred the low e coating is done on surface #2.This will allow less heat to pass through during the day.If you have a low e coating on #4 also it will further enhance the insulation properties.

A coating on#3 can improve heat gain.

Manufacturers like PPG have online calculators for calculating the u value of glazed units.

Abeer Murtaza
par Abeer Murtaza , Design Architect , Keo International Consultants - United Arab Emirates

All the EMISSIVE coatings should be used Outside, once the solar rays pass through the Normal glass, their wavelength changes and gets trapped.