What is the allowable deflection of flat slabs ?

user-image
Question ajoutée par soha mohamed
Date de publication: 2016/08/10

For slabs = Span/250 For beams = Span/360 For cantilevers = Span/450 According to Egyptian code

Nader Ali
par Nader Ali , Technical office manager , AlSafwa Contracting

As per ACI

1-flat roofs immediate deflection  due to live load = L/180

2-Roof or floors attached to non structural elements (not) likely to be damaged by large deflections due to long term deflection (dead loads+ the sustained part of live loads+creep+shrinkage effection) = L/240

3- if the roof attached to glass or cladding or Gypsumboard No.2 will be = L/480

Ahilan R
par Ahilan R , Scientific Assistant-D , Nuclear Power Corporation of India Ltd (NPCIL)

Deflection shall not exceed span/250

Muhammad Yousaf
par Muhammad Yousaf , Site Civil Engineer , Abid brothers contractors

 

Flat roofs not supporting or attached to non-structural elements likely to be damaged by large deflection.

Immediate deflection due to the live load.

L/180*

Ahmed Hassan  Mohamed Ahmed
par Ahmed Hassan Mohamed Ahmed , Project Manager (Consultant) , Cofftea

It depends on the code requirements. But defect can be controlled by limiting cracks to .3 mm width as per BS