Communiquez avec les autres et partagez vos connaissances professionnelles

Inscrivez-vous ou connectez-vous pour rejoindre votre communauté professionnelle.

Suivre

Why steel volume is not considered in concrete quantity?

user-image
Question ajoutée par SHAHID ALI
Date de publication: 2016/09/03
Imran Ahmed
par Imran Ahmed , Manager-Planning & Delay Analyst , Nesma United Industries (NUI) Saudi Arabia

,Because of following reasons:-

1) Volume of steel is negligible as compared to volume of concerete

2) Wastage of concrete while casting and in making cubes and concrete slump test.

3) A part of concrete is also remained in concrete pump pipe and concrete mixer.

4) Inaccuracy of the sections of structural elements