Communiquez avec les autres et partagez vos connaissances professionnelles

Inscrivez-vous ou connectez-vous pour rejoindre votre communauté professionnelle.

Suivre

Is there a relation between the concrete compressive strength for the columns and the slabs used in the same building)?

user-image
Question ajoutée par Mohamed Abdelmoneim , Senior Technical Structural Engineer , ALJABER Engineering
Date de publication: 2016/10/05
Jahir Raihan
par Jahir Raihan , Engineering Manager , IDCC

Hi,

This is a very interesting topic that most engineers are unaware of. So try to understand very carefully as many might disagree and some might even not understand. The slab will be subjected to only BEARING STRESS in the column-slab junction. There is no chance of slab to buckle at that point as it will be considered an endless section in width. On top of the concrete strength that junction will be having heavy reinforcements crossing through. Therefore, 50% of column fcu is enough as the column would be ok with similar fcu if it didn't had to be designed for buckling or bending. Some may ask you to use similar fcu as column at slabs junction which is ridiculous and un-engineered. Hope this helps.

RASOL RAGUIA
par RASOL RAGUIA , CONSULTANT- CIVIL ENGINEER- QC ENGINEER , SAUDI ELECTRICITY COMPANY- WOA HQ"S

yes of course  as a building it is the  column  main frame structure that hold the  slab  all times...as one whole structure

drg lkh
par drg lkh , CONSOFT Technologies Sdn. Bhd. Registration No

concrete grade increases the capacity of columns and slabs

Mohamed Kotb
par Mohamed Kotb , Senior Structural Design Engineer , Tractebel Engineering Consultancy Ltd.

Yes. The higher slab weight loaded on a certain column the higher concrete compressive strenght is required for a fixed column cross section 

Mohammed Naveed
par Mohammed Naveed , QA/QC Inspector , Dorsch Gruppe international Consultants

Yes its totally connected with each other.

Mohamed Abdelmoneim
par Mohamed Abdelmoneim , Senior Technical Structural Engineer , ALJABER Engineering

For example if i have high rise building and the required Fcu for the columns is 70MPa ,shall i use for slabs Fcu 35Mpa or less ,I think there is a relation ,and it is better also to have a reference for answers, if any .

More Questions Like This