In case of a dry sample, slump will be in the range of 25-50 mm. But in case of a wet concrete, the slump may vary from 150-175 mm. So the value of slump is specifically mentioned along the mix design and thus it should be checked as per local location.
Recommended slumps:
Reinforced foundation walls and footings:
a. Maximum Slump 75mm
b. Minimum Slump 25mm
Plain footings, caissons, and substructure walls:
a. Maximum Slump 75mm
b. Minimum Slump 25mm
Beams and reinforced walls:
a. Maximum Slump 100mm
b. Minimum Slump 25mm
Building columns:
a. Maximum Slump 100mm
b. Minimum Slump 25mm
Pavements and slabs:
a. Maximum Slump 75mm
b. Minimum Slump 25 mm
Mass Concrete Mix:
a. Maximum Slump 75mm
b. Minimum Slump 25mm