Communiquez avec les autres et partagez vos connaissances professionnelles

Inscrivez-vous ou connectez-vous pour rejoindre votre communauté professionnelle.

Suivre

What troubleshooting step must be taken if we received BBER errors intermittently on a lower order Trail.?

user-image
Question ajoutée par Irfan Ahmed Khan , Senior Network Engineer , Oman Electricity and Transmission Company
Date de publication: 2017/02/20
Bernardo Imperial
par Bernardo Imperial , Telephone Technician , Seder Group Company

SDH is a Synchronous Digital Hierarchy in case of intermittent 1 - check the power 2- Check connectivity.

Nabil Elsheikh Mohamed Elmak
par Nabil Elsheikh Mohamed Elmak , Senior Telecom Transmission and Optical Fiber Engineer , Sudanese Electricity Transmission Co. Ltd.

1- Check receive power using power meter or query it from management system, it should be in the accepted range.2- Check the connectors and ODF couplers and clean them using alcohol.

More Questions Like This