Communiquez avec les autres et partagez vos connaissances professionnelles

Inscrivez-vous ou connectez-vous pour rejoindre votre communauté professionnelle.

Suivre

How to solve column failure in a constructed structure?

user-image
Question ajoutée par طﻻل صدقي عثمان arman , رئيس مجلس اﻹدارة والمدير العام , شركة عرمان للهندسة والمقاوﻻت المحدودة
Date de publication: 2013/11/03
طﻻل صدقي عثمان arman
par طﻻل صدقي عثمان arman , رئيس مجلس اﻹدارة والمدير العام , شركة عرمان للهندسة والمقاوﻻت المحدودة

If the the dimension and steel reinforcement of the column are adequate and the problem in the compressive strength of the column, it is usually recommended to inject the column with strengthening groute rather than complete removal and reconstruction  as SAMIH said because it is sometimes not applicable but if applicable his answer is sufficient.

If the failure is due to smaller dimension or lower steel reinforcement , the proping mentioned by SAMIH will be applied and caging technique will be used. The technique depends on dwelling an external extra steel cage creating a new column and then shutter the column with the new dimension and recast it.

Muhammad Sohail
par Muhammad Sohail , Principal Engineer , BUILDCON Consulting Engineers

CFRP and Column Jacketting.

SAMIH ABBAS KOTTACKAL
par SAMIH ABBAS KOTTACKAL , STRUCTURAL ENGINEER TRAINEE , CASE STRUCTURAL ENGINEERS

IF THE COMPLETE STRUCTURE HAS NOT FAILED BY THE FAILURE OF COLUMN THEN WE SHALL GIVE PROPS FOR THE SUPPORTED STRUCTURE (SLAB)  ACCORDING TO THE LOADING CONDITION IMMEDIATELY.THEN DEMOLISH THE ENTIRE COLUMN AND RECAST IT WITH HIGH GRADE CONCRETE

More Questions Like This

Avez-vous besoin d'aide pour créer un CV ayant les mots-clés recherchés par les employeurs?