What is the maximum possible vertical suction head for a single stage centrifugal pump?

user-image
Question ajoutée par VISHNU PRADEEP , Junior Engineer , Guardian Safety & Security LLC,Dubai
Date de publication: 2014/04/18
ASIF BE Mech IEng PMP
par ASIF BE Mech IEng PMP , Projects Manager - Buildings Utilities & infrastructure , Qatar General Electricity & Water Corporation

Dear new to pumps i suppose,

its NPSH , of that pump , normally centrifugal pumps are not suction pump , they always need a positive suction head so , a NRV in suction line insures that For verical suction use positive displacement or turbine pumps which can feed a sump/tank for further application feed